| Model Items | Resistance Welding Controller | ||
|---|---|---|---|
| KCT01 | |||
| Control factor / times | 4/15 parameters / 3 times pulse control | ||
| Pressure valve drive | 2 pressure valves, DC 24V | ||
| Feedback mode | Welding transformer primary side / secondary side | ||
| Rated input voltage | V | 415V / 1 phase, ±10% | |
| Frequency | Hz | 50/60 | |
| Control parameter range | Pressure | Pressure valve 1 | |
| parameter | 1 – 15 | ||
| Initial pressure delay | cycle | 0 – 199 | |
| Initial pressure time | cycle | 0 – 199 | |
| Current upslope time | cycle | 0 – 199 | |
| Pre-heat time | cycle | 20 – 199 | |
| Pre-heat current | X 100A | 20 – 199 | |
| First cooling time | cycle | 0 – 199 | |
| Welding time | cycle | 0 – 199 | |
| Welding current | X 100A | 20 – 199 | |
| Second cooling time | cycle | 0 – 199 | |
| Temper time | cycle | 0 – 199 | |
| Temper current | X 100A | 20 – 199 | |
| Current downslope time | cycle | 0 – 199 | |
| Hold time | cycle | 1- 199 | |
| Off time | cycle | 0 – 99 | |
| Transformer turn ratio | M | 1 – 99 | |
| Number of welding circuit | 1 – 4 | ||
| Over current limit | 5 – 99%0 – 199 | ||
| Under current limit | 5 – 99% | ||
| Adding weld control while under current limit | 1 / 1 time adding weld allowed, 0 / No adding weld | ||
| Suitable welding power source | Thyristor | ||
| Start mode | Pulse, normal | ||
| Welding Mode | Spot / projection, Seam | ||
| Keep ending signal | Built-in | ||
| Power signal | Build-in | ||
| Power control signal | Build-in | ||
| Monitor function | Weld spot count, welding current, current ratio etc. | ||
| Count function | Count welding spots | ||
| Switch running mode | Welding/adjustment, discontinuous/continuous | ||